1.Identification
1.1 GHS Product identifier
Product name | 1-chloro-2-methylprop-1-ene |
---|
1.2 Other means of identification
Product number | - |
---|---|
Other names | 1-CHLORO-2-METHYL-1-PROPENE |
1.3 Recommended use of the chemical and restrictions on use
Identified uses | For industry use only. |
---|---|
Uses advised against | no data available |
1.4 Supplier's details
Company | MOLBASE (Shanghai) Biotechnology Co., Ltd. |
---|---|
Address | Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road, Xuhui District, Shanghai, China |
Telephone | +86(21)64956998 |
Fax | +86(21)54365166 |
1.5 Emergency phone number
Emergency phone number | +86-400-6021-666 |
---|---|
Service hours | Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
2.Hazard identification
2.1 Classification of the substance or mixture
Flammable liquids, Category 2
Acute toxicity - Dermal, Category 3
Skin irritation, Category 2
Eye irritation, Category 2
Acute toxicity - Inhalation, Category 1
Specific target organ toxicity – single exposure, Category 3
Carcinogenicity, Category 1B
2.2 GHS label elements, including precautionary statements
Pictogram(s) | |
---|---|
Signal word | Danger |
Hazard statement(s) | H225 Highly flammable liquid and vapour H311 Toxic in contact with skin H315 Causes skin irritation H319 Causes serious eye irritation H330 Fatal if inhaled H335 May cause respiratory irritation H350 May cause cancer |
Precautionary statement(s) | |
Prevention | P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges. P280 Wear protective gloves/protective clothing/eye protection/face protection. P264 Wash ... thoroughly after handling. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P284 [In case of inadequate ventilation] wear respiratory protection. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. |
Response | P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P370+P378 In case of fire: Use ... to extinguish. P302+P352 IF ON SKIN: Wash with plenty of water/... P312 Call a POISON CENTER/doctor/…if you feel unwell. P321 Specific treatment (see ... on this label). P361+P364 Take off immediately all contaminated clothing and wash it before reuse. P332+P313 If skin irritation occurs: Get medical advice/attention. P362+P364 Take off contaminated clothing and wash it before reuse. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313 If eye irritation persists: Get medical advice/attention. P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P310 Immediately call a POISON CENTER/doctor/… P320 Specific treatment is urgent (see ... on this label). P308+P313 IF exposed or concerned: Get medical advice/ attention. |
Storage | P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. P403+P233 Store in a well-ventilated place. Keep container tightly closed. |
Disposal | P501 Dispose of contents/container to ... |
2.3 Other hazards which do not result in classification
none
3.Composition/information on ingredients
3.1 Substances
Chemical name | Common names and synonyms | CAS number | EC number | Concentration |
---|---|---|---|---|
1-chloro-2-methylprop-1-ene | 1-chloro-2-methylprop-1-ene | 513-37-1 | none | 100% |
4.First-aid measures
4.1 Description of necessary first-aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms/effects, acute and delayed
SYMPTOMS: Symptoms of exposure to this compound may include local irritation of the eyes, mucous membranes and upper respiratory tract. It may also cause skin irritation. It may cause a burning sensation, coughing, wheezing, laryngitis, shortness of breath, headache, nausea and vomiting. Other symptoms include liver and kidney damage and central nervous system effects. It also has anesthetic properties. ACUTE/CHRONIC HAZARDS: This compound is an irritant of the skin, eyes and respiratory tract. It may be harmful by inhalation, ingestion or skin absorption. When heated to decomposition it emits toxic fumes of carbon monoxide and carbon dioxide. When heated to decomposition or exposed to air, it may emit toxic fumes of hydrogen chloride gas. It may also cause lacrimation.
4.3 Indication of immediate medical attention and special treatment needed, if necessary
/SRP:/ Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on the left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Poisons A and B/
5.Fire-fighting measures
5.1 Extinguishing media
Suitable extinguishing media
Fires involving this material can be controlled with a dry chemical, carbon dioxide or Halon extinguisher.
5.2 Specific hazards arising from the chemical
This chemical is flammable.
5.3 Special protective actions for fire-fighters
Wear self-contained breathing apparatus for firefighting if necessary.
6.Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.
6.2 Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.
6.3 Methods and materials for containment and cleaning up
PRECAUTIONS FOR "CARCINOGENS": A high-efficiency particulate arrestor (HEPA) or charcoal filters can be used to minimize amt of carcinogen in exhausted air ventilated safety cabinets, lab hoods, glove boxes or animal rooms ... Filter housing that is designed so that used filters can be transferred into plastic bag without contaminating maintenance staff is avail commercially. Filters should be placed in plastic bags immediately after removal ... The plastic bag should be sealed immediately ... The sealed bag should be labelled properly ... Waste liquids ... should be placed or collected in proper containers for disposal. The lid should be secured & the bottles properly labelled. Once filled, bottles should be placed in plastic bag, so that outer surface ... is not contaminated ... The plastic bag should also be sealed & labelled. ... Broken glassware ... should be decontaminated by solvent extraction, by chemical destruction, or in specially designed incinerators. /Chemical Carcinogens/
7.Handling and storage
7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
PRECAUTIONS FOR "CARCINOGENS": Storage site should be as close as practical to lab in which carcinogens are to be used, so that only small quantities required for ... expt need to be carried. Carcinogens should be kept in only one section of cupboard, an explosion-proof refrigerator or freezer (depending on chemicophysical properties ...) that bears appropriate label. An inventory ... should be kept, showing quantity of carcinogen & date it was acquired ... Facilities for dispensing ... should be contiguous to storage area. /Chemical Carcinogens/
8.Exposure controls/personal protection
8.1 Control parameters
Occupational Exposure limit values
no data available
Biological limit values
no data available
8.2 Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
8.3 Individual protection measures, such as personal protective equipment (PPE)
Eye/face protection
Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Respiratory protection
Wear dust mask when handling large quantities.
Thermal hazards
no data available
9.Physical and chemical properties
Physical state | PHYSICAL DESCRIPTION: Clear dark yellow to pale orange liquid. |
---|---|
Colour | Clear, colorless to brown liquid at room temperature |
Odour | no data available |
Melting point/ freezing point | no data available |
Boiling point or initial boiling point and boiling range | 68.1ºC at 760mmHg |
Flammability | no data available |
Lower and upper explosion limit / flammability limit | no data available |
Flash point | -1.11°C |
Auto-ignition temperature | no data available |
Decomposition temperature | no data available |
pH | no data available |
Kinematic viscosity | no data available |
Solubility | 1 to 5 mg/mL at 20°C |
Partition coefficient n-octanol/water (log value) | log Kow = 2.58 (est) |
Vapour pressure | 172.4 mm Hg at 25.5°C ; 265.3 mm Hg at 36.11°C |
Density and/or relative density | 0.911g/cm3 |
Relative vapour density | no data available |
Particle characteristics | no data available |
10.Stability and reactivity
10.1 Reactivity
no data available
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
DIMETHYLVINYL CHLORIDE is incompatible with strong oxidizing agents and strong bases.
10.4 Conditions to avoid
no data available
10.5 Incompatible materials
no data available
10.6 Hazardous decomposition products
When heated to decomposition /temperature unspecified/ , dimethylvinyl chloride emits highly toxic fumes of hydrochloric acid and other chlorinated compounds.
11.Toxicological information
Acute toxicity
- Oral: LD50 Mouse oral 3160 mg/kg
- Inhalation: LC50 Mouse inhalation 400 mg/cu m/ 4 hours
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
Evaluation: There is inadequate evidence in humans for the carcinogenicity of 1-chloro-2-methylpropene. There is sufficient evidence in experimental animals for the carcinogenicity of 1-chloro-2-methylpropene. Overall evaluation: 1-Chloro-2-methylpropene is possibly carcinogenic to humans (Group 2B).
Reproductive toxicity
no data available
STOT-single exposure
no data available
STOT-repeated exposure
no data available
Aspiration hazard
no data available
12.Ecological information
12.1 Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
12.2 Persistence and degradability
no data available
12.3 Bioaccumulative potential
An estimated BCF of 24 was calculated in fish for 1-chloro-2-methyl-1-propene(SRC), using an estimated log Kow of 2.58(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).
12.4 Mobility in soil
Using a structure estimation method based on molecular connectivity indices(1), the Koc of 1-chloro-2-methyl-1-propene can be estimated to be 61(SRC). According to a classification scheme(2), this estimated Koc value suggests that 1-chloro-2-methyl-1-propene is expected to have high mobility in soil.
12.5 Other adverse effects
no data available
13.Disposal considerations
13.1 Disposal methods
Product
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Contaminated packaging
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
14.Transport information
14.1 UN Number
ADR/RID: UN1993 | IMDG: UN1993 | IATA: UN1993 |
14.2 UN Proper Shipping Name
ADR/RID: FLAMMABLE LIQUID, N.O.S. |
IMDG: FLAMMABLE LIQUID, N.O.S. |
IATA: FLAMMABLE LIQUID, N.O.S. |
14.3 Transport hazard class(es)
ADR/RID: 3 | IMDG: 3 | IATA: 3 |
14.4 Packing group, if applicable
ADR/RID: II | IMDG: II | IATA: II |
14.5 Environmental hazards
ADR/RID: no | IMDG: no | IATA: no |
14.6 Special precautions for user
no data available
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
no data available
15.Regulatory information
15.1 Safety, health and environmental regulations specific for the product in question
Chemical name | Common names and synonyms | CAS number | EC number |
---|---|---|---|
1-chloro-2-methylprop-1-ene | 1-chloro-2-methylprop-1-ene | 513-37-1 | none |
European Inventory of Existing Commercial Chemical Substances (EINECS) | Listed. | ||
EC Inventory | Listed. | ||
United States Toxic Substances Control Act (TSCA) Inventory | Not Listed. | ||
China Catalog of Hazardous chemicals 2015 | Not Listed. | ||
New Zealand Inventory of Chemicals (NZIoC) | Listed. | ||
Philippines Inventory of Chemicals and Chemical Substances (PICCS) | Listed. | ||
Vietnam National Chemical Inventory | Not Listed. | ||
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) | Not Listed. |
16.Other information
Information on revision
Creation Date | Aug 14, 2017 |
---|---|
Revision Date | Aug 14, 2017 |
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Hangzhou J&H Chemical Co., Ltd.
CHINA
Purity: 98%
Lead Time: 14 Day(s)
Price: -
Henan Coreychem Co.,Ltd
CHINA
Purity: 0.98%
Lead Time: 3 Day(s)
Price: -
Shanghai Youhe Biotechnology Co., Ltd.
CHINA
Purity: 95%
Lead Time: 14 Day(s)
Price: Min $100 /g
Beijing Bailingwei Technology Co., Ltd.
CHINA
Purity: 96%
Lead Time: 7 Day(s)
Price: -
APOLLO-NMR
BRITAIN
Purity: 96%
Lead Time: 0 Day(s)
Price: Min $149 /g
Saan Chemical Technology (Shanghai) Co., Ltd.
CHINA
Purity: 98%
Lead Time: 7 Day(s)
Price: Min $201.05 /g
SynQuest Laboratories, Inc.
UNITED STATES
Purity: 96%
Lead Time: 10 Day(s)
Price: Min $223 /g
Santa Cruz Biotechnology, Inc.
UNITED STATES
Purity: 96%
Lead Time: 10 Day(s)
Price: Min $104 /g
MP BIOMEDICALS, LLC
FORT SMITH
Purity: 96%
Lead Time: 28 Day(s)
Price: Min $38 /g
Molchemical
CHINA
Purity: 96%
Lead Time: 7 Day(s)
Price: -