Home >  Chemical Encyclopedia > Miscellaneous > Chemical Reagents > Halides > 1,2-DICHLOROTETRAFLUOROETHANE
76-14-2 structure, C2Cl2F4
1,2-DICHLOROTETRAFLUOROETHANE
CAS No.: 76-14-2 Formula: C2Cl2F4 Molecular Weight: 170.92100
Search Suppliers

1,2-DICHLOROTETRAFLUOROETHANE

CAS No.:

76-14-2

Formula:

C2Cl2F4

Molecular Weight: 170.92100
Suppliers: All (7) China Suppliers (7) Price Available (1) Contractor(0)

Description

1,2-Dichlorotetrafluoroethane, or R-114, also known as cryofluorane (INN), is a chlorofluorocarbon (CFC) with the molecular formula ClF2CCF2Cl. Its primary use has been as a refrigerant. It is a non-flammable gas with a sweetish, chloroform-like odor with the critical point occurring at 145.6°C and 3.26MPa. When pressurized or cooled, it is a colorless liquid. It is listed on the Intergovernmental Panel on Climate Change's list of ozone depleting chemicals, and is classified as a Montreal Protocol Class I, group 1 ozone depleting substance.
When used as a refrigerant, R-114 is classified as a medium pressure refrigerant.
The US Navy uses R-114 in its centrifugal chillers in preference to R-11 to avoid air and moisture leakage into the system. While the evaporator of an R-11 charged chiller runs at a vacuum during operation, R-114 yields approximately 0 psig operating pressure in the evaporator.

Basic Info

Chemical Name

1,2-DICHLOROTETRAFLUOROETHANE

Synonyms

f-114; FKW114; Fron114; Ethane, 1,2-dichloro-1,1,2,2-tetrafluoro-; 1,1,2,2-tetrafluoro-1,2-dichloroethane; 1,2-dichloro-1,1,2,2-tetrafluoroethane; fc-114; R 114; 1,2-dichloro-tetrafluoroethane; Expand

CAS No.

76-14-2

Molecular Formula

C2Cl2F4

Molecular Weight

170.92100

PSA

0.00000

LogP

2.64960

Numbering system

UNII 6B5VVT93AR

Properties

Appearance & Physical State

colourless gas

Density

1.44 g/cm3

Boiling Point

3.8ºC(lit.)

Melting Point

-94ºC(lit.)

Refractive Index

1.328

Stability

Stable.

Vapor Density

5.93 (vs air)

Vapor Pressure

1427 mm Hg ( 20 °C)

Safety Info

RTECS

KI1101000

Hazard Class

2.2

Safety Statements

S59

WGK Germany

1

RIDADR

UN 1958 2

Risk Statements

R59

Hazard Codes

N

SDS 1.0

Expand

SDS 1.0

Collapse
Download/Modify | Technical supported by XiXisys.com. For US version, EU version (23 languages) and more, please refer to xixisys.com/en/sds/search

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 17, 2017

Revision Date: Aug 17, 2017

1.Identification

1.1 GHS Product identifier

Product name 1,2-DICHLOROTETRAFLUOROETHANE

1.2 Other means of identification

Product number -
Other names Fron114

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only. Intermediates
Uses advised against no data available

1.4 Supplier's details

Company MOLBASE (Shanghai) Biotechnology Co., Ltd.
Address Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road,
Xuhui District, Shanghai, China
Telephone +86(21)64956998
Fax +86(21)54365166

1.5 Emergency phone number

Emergency phone number +86-400-6021-666
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Gases under pressure: Liquefied gas

2.2 GHS label elements, including precautionary statements

Pictogram(s)
Signal word

Danger

Hazard statement(s)

H280 Contains gas under pressure; may explode if heated

Precautionary statement(s)
Prevention

none

Response

none

Storage

P410+P403 Protect from sunlight. Store in a well-ventilated place.

Disposal

none

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
1,2-DICHLOROTETRAFLUOROETHANE 1,2-DICHLOROTETRAFLUOROETHANE 76-14-2 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

Fresh air, rest. Artificial respiration may be needed. Refer for medical attention.

In case of skin contact

ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Refer for medical attention .

In case of eye contact

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

If swallowed

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

4.2 Most important symptoms/effects, acute and delayed

Prolonged exposure can cause narcotic effect or rapid suffocation. (USCG, 1999)

4.3 Indication of immediate medical attention and special treatment needed, if necessary

Victims of freon inhalation require management for hypoxic, CNS anesthetic, & cardiac symptoms. Patients must be removed from the exposure environment, & high flow supplemental oxygen should be utilized. The respiratory system should be evaluated for injury, aspiration, or pulmonary edema & treated appropriately. CNS findings should be treated supportively. A calm environment with no physical exertion is imperative to avoid increasing endogenous adrenegic levels. Exogenous adrenergic drugs must not be used to avoid inducing sensitized myocardial dysrhythmias. Atropine is ineffective in treating bradyarrhythmias. For ventricular dysrhythmias, diphenylhydantoin & countershock may be effective. Cryogenic dermal injuries should be treated by water bath rewarming at 40-42°C until vasodilatory flush has returned. Elevation of the limb & standard frostbite management with late surgical debridement should be utilized. Ocular exposure requires irrigation & slit lamp evaluation for injury. /Freons/

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Firefighters should wear self-contained, NIOSH-approved breathing apparatus for protection against suffocation and possible toxic decomposition products. Proper eye and skin protection should be provided. Use water spray to keep fire-exposed containers cool.

5.2 Specific hazards arising from the chemical

Excerpt from ERG Guide 126 [Gases - Compressed or Liquefied (Including Refrigerant Gases)]: Some may burn but none ignite readily. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2016)

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Ventilation. NEVER direct water jet on liquid. Do NOT let this chemical enter the environment. Personal protection: chemical protection suit including self-contained breathing apparatus.

6.3 Methods and materials for containment and cleaning up

If ... spilled or leaked, the following steps should be taken: 1. Ventilate area of spill or leak. 2. If the gas is leaking, stop the flow. 3. If the liquid is spilled or leaked, allow to vaporize.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Fireproof if in building. Cool.Store in a cool, well-ventilated area of low fire risk and out of direct sunlight. Protect cylinder and its fittings from physical damage. Storage in subsurface locations should be avoided. Close valve tightly after use and when empty.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

Recommended Exposure Limit: 10 Hour Time-Weighted Average: 1000 ppm (7000 mg/cu m).

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state colourless gas
Colour Colorless gas ... [Note: A liquid below 38 degrees F. Shipped as a liquefied compressed gas]
Odour Faint, ether-like odor at high concentrations
Melting point/ freezing point -94ºC(lit.)
Boiling point or initial boiling point and boiling range 3.8ºC(lit.)
Flammability Nonflammable GasNot combustible. Heating will cause rise in pressure with risk of bursting. Gives off irritating or toxic fumes (or gases) in a fire.
Lower and upper explosion limit / flammability limit no data available
Flash point no data available
Auto-ignition temperature no data available
Decomposition temperature no data available
pH no data available
Kinematic viscosity 0.012 cP at 60°C (gas)
Solubility Souble in alcohol, ether
Partition coefficient n-octanol/water (log value) log Kow = 2.82
Vapour pressure 1427 mm Hg ( 20 °C)
Density and/or relative density 1.44 g/cm3
Relative vapour density 5.93 (vs air)
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Conditions contributing to instability: heat.

10.3 Possibility of hazardous reactions

The gas is heavier than air and may accumulate in lowered spaces causing a deficiency of oxygen.1,2-DICHLORO-1,1,2,2-TETRAFLUOROETHANE is chemically inert in many situations, but can react violently with strong reducing agents such as the very active metals and the active metals. Can react with strong oxidizing agents or weaker oxidizing agents under extremes of temperature. The reaction of aluminum with various halogenated hydrocarbons produces a self-sustaining reaction with sufficient heat to melt aluminum pieces, examples of other halogenated hydrocarbons are fluorotrichloromethane, dichlorodifluoromethane, chlorodifluoromethane, tetrafluoromethane. The vigor of the reaction appears to be dependent on the combined degree of fluorination and the vapor pressure [Chem. Eng. News 39(27):44(1961)].

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

Incompatible with chemically-active metals such as sodium, potassium, calcium, powdered aluminum, zinc and magnesium; acids; acid fumes.

10.6 Hazardous decomposition products

Dangerous; When heated to decomp ... they evolve highly toxic /hydrogen/ chloride fumes. /Chlorides/

11.Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: LC50 Rabbit inhalation 75 pph/30 min
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

A4: Not classifiable as a human carcinogen. /Dichorotetrafluoroethane/

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

AEROBIC: 1,2-Dichloro-1,1,2,2-tetrafluoroethane was reported to be not readily biodegradable using an activated sludge inoculum in the Japanese MITI test(1).

12.3 Bioaccumulative potential

Measured BCF values ranging from 16 to 32 and 15 to 28 at 1,2-dichloro-1,1,2,2-tetrafluoroethane exposure levels of 400 and 40 mg/L, respectively, were reported using carp (Cyprinus carpio) which were exposed over an 6-week period(1). According to a classification scheme(2), this BCF suggests the potential for bioconcentration in aquatic organisms is low to moderate(SRC).

12.4 Mobility in soil

The Koc of 1,2-dichloro-1,1,2,2-tetrafluoroethane is estimated as 280(SRC), using a log Kow of 2.82(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that 1,2-dichloro-1,1,2,2-tetrafluoroethane is expected to have moderate mobility in soil.

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: UN1958 IMDG: UN1958 IATA: UN1958

14.2 UN Proper Shipping Name

ADR/RID: 1,2-DICHLORO-1,1,2,2- TETRAFLUOROETHANE (REFRIGERANT GAS R 114)
IMDG: 1,2-DICHLORO-1,1,2,2- TETRAFLUOROETHANE (REFRIGERANT GAS R 114)
IATA: 1,2-DICHLORO-1,1,2,2- TETRAFLUOROETHANE (REFRIGERANT GAS R 114)

14.3 Transport hazard class(es)

ADR/RID: 2 IMDG: 2 IATA: 2

14.4 Packing group, if applicable

ADR/RID: unknown IMDG: unknown IATA: unknown

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
1,2-DICHLOROTETRAFLUOROETHANE 1,2-DICHLOROTETRAFLUOROETHANE 76-14-2 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Not Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 17, 2017
Revision Date Aug 17, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.

MSDS

Expand
13C NMR : PredictExpand

NMR Spectrum 13C NMR : Predict

Collapse
76-14-2 NMR spectrum
More

GC Analysis

Total 4 Documents >>
Column type Active phase Temperature (°C) Retention Index (I) Temperature Control Method
Capillary BP-1 - 359. temperature ramp
Capillary SPB-1 - 352. custom temperature program
Capillary SPB-1 - 352. custom temperature program
Capillary SPB-1 - 361. custom temperature program
Recommended Suppliers
More Suppliers>>