1.Identification
1.1 GHS Product identifier
Product name | perchloryl fluoride |
---|
1.2 Other means of identification
Product number | - |
---|---|
Other names | EINECS 231-526-0 |
1.3 Recommended use of the chemical and restrictions on use
Identified uses | For industry use only. |
---|---|
Uses advised against | no data available |
1.4 Supplier's details
Company | MOLBASE (Shanghai) Biotechnology Co., Ltd. |
---|---|
Address | Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road, Xuhui District, Shanghai, China |
Telephone | +86(21)64956998 |
Fax | +86(21)54365166 |
1.5 Emergency phone number
Emergency phone number | +86-400-6021-666 |
---|---|
Service hours | Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours). |
2.Hazard identification
2.1 Classification of the substance or mixture
Oxidizing gases, Category 1
Acute toxicity - Inhalation, Category 2
2.2 GHS label elements, including precautionary statements
Pictogram(s) | |
---|---|
Signal word | Danger |
Hazard statement(s) | H270 May cause or intensify fire; oxidizer H330 Fatal if inhaled |
Precautionary statement(s) | |
Prevention | P220 Keep away from clothing and other combustible materials. P244 Keep valves and fittings free from oil and grease. P260 Do not breathe dust/fume/gas/mist/vapours/spray. P271 Use only outdoors or in a well-ventilated area. P284 [In case of inadequate ventilation] wear respiratory protection. |
Response | P370+P376 In case of fire: Stop leak if safe to do so. P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P310 Immediately call a POISON CENTER/doctor/… P320 Specific treatment is urgent (see ... on this label). |
Storage | P403 Store in a well-ventilated place. P403+P233 Store in a well-ventilated place. Keep container tightly closed. |
Disposal | P501 Dispose of contents/container to ... |
2.3 Other hazards which do not result in classification
none
3.Composition/information on ingredients
3.1 Substances
Chemical name | Common names and synonyms | CAS number | EC number | Concentration |
---|---|---|---|---|
perchloryl fluoride | perchloryl fluoride | 7616-94-6 | none | 100% |
4.First-aid measures
4.1 Description of necessary first-aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
Fresh air, rest. Half-upright position. Refer for medical attention.
In case of skin contact
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes. Refer for medical attention .
In case of eye contact
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms/effects, acute and delayed
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]: TOXIC; may be fatal if inhaled or absorbed through skin. Fire will produce irritating, corrosive and/or toxic gases. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Runoff from fire control may cause pollution. (ERG, 2016)
4.3 Indication of immediate medical attention and special treatment needed, if necessary
Absorption, Distribution and Excretion
CAN BE ABSORBED THROUGH SKIN.
5.Fire-fighting measures
5.1 Extinguishing media
Suitable extinguishing media
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]: SMALL FIRE: CAUTION: These materials do not burn but will support combustion. Some will react violently with water. Contain fire and let burn. If fire must be fought, water spray or fog is recommended. Water only; no dry chemical, CO2 or Halon®. Do not get water inside containers. Move containers from fire area if you can do it without risk. Damaged cylinders should be handled only by specialists. FIRE INVOLVING TANKS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Do not direct water at source of leak or safety devices; icing may occur. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2016)
5.2 Specific hazards arising from the chemical
Excerpt from ERG Guide 124 [Gases - Toxic and/or Corrosive - Oxidizing]: Substance does not burn but will support combustion. Vapors from liquefied gas are initially heavier than air and spread along ground. These are strong oxidizers and will react vigorously or explosively with many materials including fuels. May ignite combustibles (wood, paper, oil, clothing, etc.). Some will react violently with air, moist air and/or water. Cylinders exposed to fire may vent and release toxic and/or corrosive gas through pressure relief devices. Containers may explode when heated. Ruptured cylinders may rocket. (ERG, 2016)
5.3 Special protective actions for fire-fighters
Wear self-contained breathing apparatus for firefighting if necessary.
6.Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.
6.2 Environmental precautions
Evacuate danger area! Consult an expert! Personal protection: complete protective clothing including self-contained breathing apparatus. Ventilation. NEVER direct water jet on liquid.
6.3 Methods and materials for containment and cleaning up
Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.
7.Handling and storage
7.1 Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Fireproof if in building.USUALLY STORED IN CYLINDERS AS LIQUID UNDER PRESSURE.
8.Exposure controls/personal protection
8.1 Control parameters
Occupational Exposure limit values
Recommended Exposure Limit: 10 Hr Time-Weighted Avg: 3 ppm (14 mg/cu m).
Recommended Exposure Limit: 15 Min Short-Term Exposure Limit: 6 ppm (28 mg/cu m).
Biological limit values
no data available
8.2 Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
8.3 Individual protection measures, such as personal protective equipment (PPE)
Eye/face protection
Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Respiratory protection
Wear dust mask when handling large quantities.
Thermal hazards
no data available
9.Physical and chemical properties
Physical state | Perchloryl fluoride is a colorless, non corrosive gas with a characteristic sweet odor. Contact with the material may cause irritation to skin, eyes, and mucous membranes. It is very toxic by inhalation and skin absorption. Under prolonged exposure to fire or intense heat the containers may violently rupture and rocket. |
---|---|
Colour | COLORLESS GAS |
Odour | CHARACTERISTIC SWEET ODOR |
Melting point/ freezing point | -146ºC |
Boiling point or initial boiling point and boiling range | -46.8ºC |
Flammability | Nonflammable Gas, but will support combustion.Not combustible but enhances combustion of other substances. Gives off irritating or toxic fumes (or gases) in a fire. |
Lower and upper explosion limit / flammability limit | no data available |
Flash point | no data available |
Auto-ignition temperature | no data available |
Decomposition temperature | no data available |
pH | no data available |
Kinematic viscosity | 3.91X10-3 Pa.s (liq) @ melting point |
Solubility | 0.06 % (NIOSH, 2016) |
Partition coefficient n-octanol/water (log value) | no data available |
Vapour pressure | 10.5 atm (NIOSH, 2016) |
Density and/or relative density | 1.434 |
Relative vapour density | 3.64 |
Particle characteristics | no data available |
10.Stability and reactivity
10.1 Reactivity
no data available
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
MODERATE; WHILE NONINFLAMMABLE, IT SUPPORTS COMBUSTION. IT IS POWERFUL OXIDIZER.PERCHLORYL FLUORIDE is a propellant; a powerful oxidant. It ignites upon contact with alcohols, amines, ammonia, beryllium alkyls, boranes, dicyanogen, hydrazines, hydrocarbons, hydrogen, nitroalkanes, powdered metals, silanes, or thiols [Bretherick 1979. p.174]. It may generate hydrofluoric acid if it comes into contact with water.
10.4 Conditions to avoid
no data available
10.5 Incompatible materials
POWERFUL OXIDIZING AGENT.
10.6 Hazardous decomposition products
WHEN HEATED TO DECOMP, IT EMITS HIGHLY TOXIC FUMES OF CHLORIDES & FLUORIDES.
11.Toxicological information
Acute toxicity
- Oral: no data available
- Inhalation: Acute inhalation LC50 values for rodents exposed to perchloryl fluoride for 4 hours were 385 ppm in rats and 630 ppm in mice.
- Dermal: no data available
Skin corrosion/irritation
no data available
Serious eye damage/irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
no data available
Reproductive toxicity
no data available
STOT-single exposure
no data available
STOT-repeated exposure
no data available
Aspiration hazard
no data available
12.Ecological information
12.1 Toxicity
- Toxicity to fish: no data available
- Toxicity to daphnia and other aquatic invertebrates: no data available
- Toxicity to algae: no data available
- Toxicity to microorganisms: no data available
12.2 Persistence and degradability
no data available
12.3 Bioaccumulative potential
no data available
12.4 Mobility in soil
no data available
12.5 Other adverse effects
no data available
13.Disposal considerations
13.1 Disposal methods
Product
The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.
Contaminated packaging
Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.
14.Transport information
14.1 UN Number
ADR/RID: UN3157 | IMDG: UN3157 | IATA: UN3157 |
14.2 UN Proper Shipping Name
ADR/RID: LIQUEFIED GAS, OXIDIZING, N.O.S. |
IMDG: LIQUEFIED GAS, OXIDIZING, N.O.S. |
IATA: LIQUEFIED GAS, OXIDIZING, N.O.S. |
14.3 Transport hazard class(es)
ADR/RID: 2.2 | IMDG: 2.2 | IATA: 2.2 |
14.4 Packing group, if applicable
ADR/RID: unknown | IMDG: unknown | IATA: unknown |
14.5 Environmental hazards
ADR/RID: no | IMDG: no | IATA: no |
14.6 Special precautions for user
no data available
14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
no data available
15.Regulatory information
15.1 Safety, health and environmental regulations specific for the product in question
Chemical name | Common names and synonyms | CAS number | EC number |
---|---|---|---|
perchloryl fluoride | perchloryl fluoride | 7616-94-6 | none |
European Inventory of Existing Commercial Chemical Substances (EINECS) | Listed. | ||
EC Inventory | Listed. | ||
United States Toxic Substances Control Act (TSCA) Inventory | Listed. | ||
China Catalog of Hazardous chemicals 2015 | Listed. | ||
New Zealand Inventory of Chemicals (NZIoC) | Not Listed. | ||
Philippines Inventory of Chemicals and Chemical Substances (PICCS) | Not Listed. | ||
Vietnam National Chemical Inventory | Not Listed. | ||
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) | Not Listed. |
16.Other information
Information on revision
Creation Date | Aug 18, 2017 |
---|---|
Revision Date | Aug 18, 2017 |
Abbreviations and acronyms
- CAS: Chemical Abstracts Service
- ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
- RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
- IMDG: International Maritime Dangerous Goods
- IATA: International Air Transportation Association
- TWA: Time Weighted Average
- STEL: Short term exposure limit
- LC50: Lethal Concentration 50%
- LD50: Lethal Dose 50%
- EC50: Effective Concentration 50%
References
- IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
- HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
- IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
- eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
- CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
- ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
- ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
- Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
- ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Hangzhou DayangChem Co., Ltd
CHINA
Purity: 98%
Lead Time: 7 Day(s)
Price: -
Henan Coreychem Co.,Ltd
CHINA
Purity: 98%
Lead Time: 3 Day(s)
Price: -